5.5 Maintenance
The MP 2000 does not require special maintenance, ex-
cept for the following:
-periodic cleaning, approximately every 10 million charac-
ters, of the printhead bearing rod with isopropylic alcohol
or similar.
verication of the distance between printhead and prin-
ting plate (if the printer has suffered major shock or whe-
never an appreciable occurrence of bad quality printing
is experienced). The distance, measured by a thickness
gauge with the printer closed and no inked ribbon inter-
posed, should be 0.55 mm +/- 0.05 mm.
-periodic cleaning of the printer’s mechanism, in order to
avoid dust particles, paper clips and the like, can cause
mechanism malfunctions.